AS 4586 SPC Flooring: Australian Slip and Fire Test Guide

Slip resistance, dry friction and AS ISO 9239 reaction-to-fire results for Australian buyers.

Quick answer: Emosin has SGS test reports for 7.0 mm SPC flooring covering Australian slip resistance and reaction-to-fire testing. The AS 4586 wet pendulum test reported a mean SRV of 29 and classification P2. A separate dry friction test reported a mean coefficient of friction of 0.63 and classification D1. An AS ISO 9239.1-1 reaction-to-fire report is also available for a 7.0 mm SPC sample.

These reports provide useful test evidence for Australian and New Zealand buyers, but they do not replace the project specification. The classification required depends on the building use, location, substrate, installation and the applicable local requirements.

Important scope: Each report relates to the sample, thickness, surface and test conditions stated in that report. Confirm the final product and installation system with Emosin before using a result in a project submission.

AS 4586 slip resistance results

The wet pendulum report uses AS 4586-2013+A1:2017 Appendix A. Five test pieces measuring 200 × 150 × 7.0 mm were tested with a Slider 55 at 22°C. The report states a mean SRV of 29 and a class of P2.

Report Test Result Classification
SHIN2507001843CM01_EN AS 4586 wet pendulum, Appendix A Mean SRV 29 P2
XMIN2507001715CM01_EN AS 4586 dry floor friction, Appendix B Mean coefficient of friction 0.63 D1

The product tested was a 7.0 mm SPC flooring sample. That detail matters: changing the thickness, surface texture, wear layer or backing can change the tested system. A report for another SPC construction should not be treated automatically as evidence for the final product.

What P2 and D1 mean in a tender

P2 is the wet-pendulum classification stated in the report. D1 is the dry-friction classification stated in the report. Neither label should be read as “suitable for every area” or as a universal building-code approval.

For a tender, state the required classification, the test standard and the floor area. Then match those requirements to the report. A project may specify a higher class for an entrance, bathroom, kitchen, ramp or commercial circulation area. The final decision belongs to the project designer and the applicable local rules.

AS ISO 9239 reaction-to-fire test

The SGS fire report AJFTS25004878R01_EN, dated 8 August 2025, covers the reaction-to-fire test method AS ISO 9239.1-1:2003(R2016). The report describes a brown SPC flooring sample, 7.0 mm thick, 12.8 kg/m² area density, 1050 × 230 × 7.0 mm, with a wood-grain surface, mechanically fixed to approximately 9 mm fibre cement board without joints.

Reported test data Recorded result
Critical heat flux, CHF ≥11.0 kW/m²
Average smoke integral 17.1 % × min
Flame-front distance at 30 minutes 90 / 30 / 70 / 80 mm across S1–S4

The report is a test report, not a project fire certificate. It should be reviewed with the full test assembly, project specification and any national or local classification requirement that applies to the intended use.

What Australian buyers should verify

  1. Product type and nominal thickness: the supplied reports are for 7.0 mm SPC samples.
  2. Surface and construction: the fire report describes a wood-grain surface and a specific mounting assembly.
  3. Required slip class: match the project area and specification to P2/D1, or request additional testing if a higher class is required.
  4. Fire requirement: confirm whether the project needs a particular reaction-to-fire classification or a full system assessment.
  5. Report validity and number: use the exact SGS report references in the submittal.
  6. Final quotation: attach the correct report to the correct SKU and installation method.

If the project requires a different thickness, surface, underlay or installation system, ask Emosin to confirm whether the existing report is applicable or whether additional testing is needed.

Why these reports matter to Emosin customers

Australian commercial projects often ask for more than a product brochure. A buyer needs a traceable document that states the test method, the sample and the result. Emosin’s document set gives the procurement team a starting point:

  • SPC product information for the project brief;
  • AS 4586 wet and dry slip reports for floor classification discussions;
  • AS ISO 9239 reaction-to-fire test data for technical review;
  • a named factory, QC process and current certificate register for supplier verification.

Use the Australia and New Zealand market page for product and delivery requirements, and the certifications page for the current document register.

Frequently asked questions

Is P2 suitable for every Australian commercial floor?

No. P2 is the class stated in this wet-pendulum report for the tested sample. The required class depends on the project area, use and specification.

Can D1 be used as a wet-area classification?

D1 is the dry-friction result reported under the stated method. Wet-area and project requirements need to be checked separately against the relevant standard and specification.

Does the fire report cover every SPC product?

No. It applies to the sample and mounting details stated in the report. A different construction or installation may require an updated assessment.